SKU: For Ordering Information see above
HD2

FluorChem® HD2 Imaging
System Sensitive Chemiluminescent Imaging

Offering best-in-class resolution, sensitivity and dynamic range, the FluorChem HD2 System is optimized to image chemiluminescent blots at speeds that surpass film.

  • Fast lens technology provides the ability to rapidly detect and quantitate chemiluminescent westerns without the need for film and a scanner
  • Protocol driven analysis reducing imaging time by remembering the settings for imaging your assay
  • Advanced AlphaView software provides the tools for analyzing your data, and provides the ability to save your analysis protocols for your assay
  • Faster, more sensitive than film and quantifiable.
  • Applications: Chemiluminescent Westerns, 96-Well Plates, 2-D Gels, Colony Counting, Protein Gels

HD2 Fast LensThe Digital Darkroom

The FluorChem HD2 System delivers higher sensitivity and a broader dynamic range than film can provide at similar exposure times. Captured images are saved digitally, making them easy to import into presentations and reports.

When low level sample detection is required, FluorChem HD2 offers the highest sensitivity without sacrificing speed for chemiluminescent applications.

FluorChem Systems use large aperture fixed lenses to increase the speed of light collection. This reduces acquisition times and provides image quality that is far superior to typical zoom lenses.

 

HD2 Blot

 

 

 

 

Slot blot of antibody coupled to HRP spotted on PVDF membrane. ChemiGlow® Chemiluminescent Substrate was used.

 

 

 

 

 

Stronger Signal in Less Time.

 

 

 

 

 

Equivalent Signal in the Same Time.

 

 

 

 

Features And Benefits

  • Motorized optics and Automatic Image Capture Software provide ease of use when imaging
  • Multiple lens options allow systems to be customized for specific applications
  • Five-position filter wheel provides UV fluorescent imaging versatility
  • System upgrades allow expansion of capabilities as application needs change

Filters

 

 

 

Orange Filter (590 nm50 nm Band Pass)

Ethidium Bromide and SYPRO Orange

Red Filter (620 nm40 nm Band Pass)

SYPRO Red, SYPRO Ruby, Texas Red (Optional)

Green Filter (537 nm35 nm Band Pass)

Fluorescein, SYBR Gold, and GFP (Optional

Blue Filter (460 nm40 nm Band Pass)

Hoechst Blue and Carbohydrate Gels (Optional)

 

Specifications

Specifications: 

Description

Alphaimager HD-2

Dimensions external HxWxD, mm

100 x 50 x 38 cm

Field of View (Fast Lense)

15 x 15 cm

Field of View (motorized lens)

26 x 23 cm

Capacity

 

Weight, kg

45kgs

Wavelength

 

 

 

Scientific grade Camera

 

Pixel size

7.4 Micron Square

A/D Convertor

16 bit

Resolution

4.19 Megapixels

Absolutely Regulated

-25Degrees for consistent imaging over long exposures and variable ambient.

Light Sources

 

UV Transilluminator

302/365 nm Dual Wavelength UV Transilluminator (42 cm x 31 cm)

Epi White Light

Dual Epi White Light Modules

Trans White Light

Fold Down White Light Table(standard)

Epi UV

254 nm, 365 nm or Dual 254/365 nm (Optional)

 

 

Cabinet

 

Filter Position

Automated 5-position

Construction

1pieces light tight casting. Upgradeable to Flourescent FC-Q.

 

 

Optics

 

Manual

Manual fixed 50 mm f/0.95

(standard Fast Lense optimized for Chemi)

Manual

Manual

28 mm f/1.8 (option lense for flexibility and larger FOV)

 

Ordering Information

Ordering Information: 

Part No

Description

 

92-15410-00

 

FluorChem HD2 System (Lens must be ordered separately) includes a 4.19 mP camera with 16-bit a/D, cooled to -25°C absolute

and regulated, orange filter, white light table, adjustable tray kit, 365/302 nm dual-wavelength, dual-intensity uv transilluminator, epi white

lights, alphaview hD2 Software and two stand alone licenses

 

92-13604-00

FluorChem HD2 System with Manual Fixed Lens 50 mm, f/0.95 includes a 4.19 mP camera with 16-bit a/D, cooled to -25°C

absolute and regulated, 50 mm, f/0.95 fixed lens, orange filter, white light table, adjustable tray kit, 365/302 nm dual-wavelength, dualintensity uv transilluminator, epi white lights, alphaview hD2 Software and two stand alone licenses

 

60-14329-00

FluorChem Xplor Upgrade for FluorChem HD2 extends FluorChem hD2 capability to include large format 1D (24 x 24 cm) and

2D protein gel imaging. includes f/1.8 manual fixed optics, red filter, XplorBright, Xploruv, sample tray, Xplor Software and Xpedition 2D

analysis Software

 

92-14155-00

FluorChem Q Upgrade for FluorChem HD2 includes multiimage®

iii Cabinet with 3 specific epi excitation channels, four emission

filters, white light table, sample tray, epi white lights, and alphaview Q Software with two stand alone licenses.

91-13591-00

Manual Fixed Lens 50 mm, f/0.95

91-14473-00

Motorized Fixed Lens 50 mm, f/0.95

91-12908-00

Manual Fixed Lens 28 mm, f/1.8

91-13166-00

Motorized Fixed Lens 28 mm, f/1.8

 

 

 

10-14794-00

Computer Comes pre-installed with alphaview System Software and is configured for optimal imaging system performance.