Login

Language:
Currency:
VAT Mode:
NanoDrop ND3300

 E-mail this product to a friend


     

NanoDrop 3300


Micro-Volume Full-Spectrum Fluorospectrometer

Using our patented sample retention technology,
the versatile and cost-effective Thermo Scientific NanoDrop 3300 Fluorospectrometer makes broad spectrum fluorescence analysis quick and easy. It offers:
  • Sample size as small as 1 µl
  • Mass detection limit more than one order of magnitude
    lower than conventional fluorometers
  • UV, Blue and White LED excitation, covering a broad wavelength range
  • No filter changes, no monochromator
  • Ability to analyze multiple emission profiles from a
    single sample
  • Simplicity of use – just pipette and wipe
  • User-friendly software
  • Ability to run diverse applications – multiple
    fluorophores, Molecular Beacon Probes, FRET and more
  • A cost-effective, unique alternative to high-end
    fluorometers or complicated lab-built systems with microscopes and CCD cameras

 

The NanoDrop 3300 in the lab

How It Works


The sample retention system used by the Thermo Scientific NanoDrop 3300 Fluorospectrometer enables analysis of extremely small sample volumes (1-2 µl) without the use of cuvettes  or capillaries. Preparing the instrument for another measurement simply involves cleaning the sample off with an ordinary lab wipe. The system saves on expenses associated with disposables as well as on time and effort spent cleaning  quartz cuvettes.





With the apparatus arm open, a droplet of sample is pipetted onto the measurement pedestal.

When the apparatus is closed, the sample arm slightly compresses the droplet and a liquid column is drawn. Surface tension alone holds the sample in place for the spectral measurement. The spectral measurement is then made and quantification is made based a sample length of 1 mm.

When the measurement is complete, the apparatus arm is opened and the sample is simply wiped from both the upper bushing and lower pedestal using an ordinary dry laboratory wipe.

Since the sample is not contained in a secondary vessel, the sample directly wets the system optics, reducing the variations resulting from changing and/or repositioning cuvettes. When the sample is removed, the optics can be easily cleaned making it possible to measure successive sample concentrations varying by more than 1000 fold in concentration with no carryover.
 

Specifications


Instrument Type   Fluorospectrometer  
Minimum Sample Size 1 µl
Light Sources 3 light emitting diodes (LEDs)
Excitation Maxima UV: 365 nm
Blue: 470 nm
White 460-650 nm
Detector Type 2048 - element linear silicon CCD array
Wavelength Range 400-750 nm
Wavelength Accuracy 1 nm
Spectral resolution 8 nm (FWHM at Hg 546 nm)
Fluorescence Precision < 5% CV (10 nM fluorescein)
Detection Limit < 1 fmol fluorescein
Measurement Cycle Time 2 - 10 seconds
Dimensions (footprint) 14 cm X 20 cm
Weight 1.5 kg
Sample Pedestal Material of Construction 303 stainless steel and quartz fiber
Operating Voltage 5 vdc (supplied by USB port, no external power supply)
Operating Power Consumption 2 W
Standby Power Consumption 1 W
Software Compatibility Microsoft Windows® 2000, XP, and Vista (32 bit)
UL/CSA and CE All units are approved to these standards